TY - JOUR T1 - Effect of mechanical ventilator weaning protocols on respiratory outcomes in infants and children: A randomized controlled trial AU - Randolph AG, Wypij D, Venkataraman ST, et al Y1 - 2002/11/27 N1 - 10.1001/jama.288.20.2561 JO - JAMA SP - 2561 EP - 2568 VL - 288 IS - 20 N2 - Context  Ventilator management protocols shorten the time required to wean adult patients from mechanical ventilation. The efficacy of such weaning protocols among children has not been studied.Objective  To evaluate whether weaning protocols are superior to standard care (no defined protocol) for infants and children with acute illnesses requiring mechanical ventilator support and whether a volume support weaning protocol using continuous automated adjustment of pressure support by the ventilator (ie, VSV) is superior to manual adjustment of pressure support by clinicians (ie, PSV).Design and Setting  Randomized controlled trial conducted in the pediatric intensive care units of 10 children's hospitals across North America from November 1999 through April 2001.Patients  One hundred eighty-two spontaneously breathing children (<18 years old) who had been receiving ventilator support for more than 24 hours and who failed a test for extubation readiness on minimal pressure support.Interventions  Patients were randomized to a PSV protocol (n = 62), VSV protocol (n = 60), or no protocol (n = 60).Main Outcome Measures  Duration of weaning time (from randomization to successful extubation); extubation failure (any invasive or noninvasive ventilator support within 48 hours of extubation).Results  Extubation failure rates were not significantly different for PSV (15%), VSV (24%), and no protocol (17%) (P = .44). Among weaning successes, median duration of weaning was not significantly different for PSV (1.6 days), VSV (1.8 days), and no protocol (2.0 days) (P = .75). Male children more frequently failed extubation (odds ratio, 7.86; 95% confidence interval, 2.36-26.2; P<.001). Increased sedative use in the first 24 hours of weaning predicted extubation failure (P = .04) and, among extubation successes, duration of weaning (P<.001).Conclusions  In contrast with adult patients, the majority of children are weaned from mechanical ventilator support in 2 days or less. Weaning protocols did not significantly shorten this brief duration of weaning. SN - 0098-7484 M3 - doi: 10.1001/jama.288.20.2561 UR - http://dx.doi.org/10.1001/jama.288.20.2561 ER -