Clinical Review | Clinician's Corner

Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A1c FREE

Christopher D. Saudek, MD; Rachel L. Derr, MD; Rita R. Kalyani, MD
[+] Author Affiliations

Clinical Review Section Editor: Michael S. Lauer, MD. We encourage authors to submit papers for consideration as a Clinical Review. Please contact Michael S. Lauer, MD, at lauerm@ccf.org.

Author Affiliations: Division of Endocrinology and Metabolism, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Md.

More Author Information
JAMA. 2006;295(14):1688-1697. doi:10.1001/jama.295.14.1688.
Text Size: A A A
Published online

Context With the increasing prevalence of diabetes, successful management of blood glucose control is increasingly important. Current approaches to assessing glycemia include the use of self-monitoring of blood glucose (SMBG) and hemoglobin A1c (HbA1c).

Objectives To assess the evidence underlying the use of these 2 modalities, to evaluate confounders and sources of error in each test, to describe upcoming developments, and to reach evidence-based conclusions on their optimal use.

Data Sources, Study Selection, and Data Extraction Reports identified from MEDLINE searches (1976-2005) using relevant terms were selected for quality and relevance to the stated questions. Particular attention was paid to larger cohort studies, clinical trials, meta-analyses, and established recommendations.

Data Synthesis If used properly SMBG gives an acceptably accurate reflection of immediate plasma glucose levels. Study results vary, but in general, the evidence supports a positive effect of regular SMBG for improving glycemia, particularly in individuals treated with insulin. The best timing of SMBG and its frequency are controversial issues, but the clinical recommendation is for regular monitoring with frequency depending on the treatment and the instability of glycemia. In the relatively near term, SMBG could gradually be replaced by continuous glucose monitoring. HbA1c measures long-term glycemic control, reflecting a time-weighted mean over the previous 3 to 4 months. There are a number of physiologic and methodologic confounders that can affect HbA1c, but standardization of assays has been well established. The main value of HbA1c is its use as a predictor of diabetic complications and the proven effect of improved control of HbA1c on complication risk. A reasonable target value for HbA1c is less than 7%. A new method for measuring HbA1c may cause significant changes in the recommended levels, the numbers reported, and even the name of the test.

Conclusion Assessing glycemia in diabetes can be a challenge, but approaches are available that promote successful management of blood glucose and may thereby lead to a significant reduction in morbidity and mortality related to diabetes.

Figures in this Article

Quiz Ref IDThe prevalence of diabetes is increasing at an alarming rate, as are the associated personal and societal costs. While diabetes care should address a number of risk factors (dyslipidemia, blood pressure, tobacco use, etc), hyperglycemia itself not only defines the disease but is the cause of its most characteristic symptoms and long-term complications. Good glycemic control reduces the incidence and progression of microvascular disease in both type 1 and 2 diabetes.14 The impact of hyperglycemia on cardiovascular disease is also becoming increasingly evident.57 Although the Diabetes Control and Complications Trial found an increased incidence of hypoglycemia accompanying intensive glycemic control,8 participants rated their overall quality of life as improved by better glycemic control.9

Assessing glycemia in diabetes, however, has always been a challenge. Until about 1910, overt symptoms of hyperglycemia were the only available metric of diabetic control.10 The development of urine glucose testing allowed documentation of severe hyperglycemia, but was seriously limited by being only semiquantitative, retrospective, and significantly affected by urine concentration. An important change in diabetes care occurred in the 1970s and 1980s as 2 methods became available: self-monitoring of blood glucose (SMBG) and hemoglobin A1c (HbA1c) testing. Home urine testing became obsolete except when testing for ketones in situations of suspected ketoacidosis.

The information derived from these 2 assessment tools is fundamentally different. SMBG reveals the immediate, hour-to-hour blood glucose, which in people without diabetes varies only about 50% throughout the normal day but may vary 10-fold in patients with diabetes. Long-term or month-to-month glycemia is assessed by HbA1c. In this review, we summarize the theoretical and methodological basis, standardization and confounders, evidence of clinical utility and controversies, and recommendations for use of SMBG and HbA1c. We also describe important advances coming in the near future.

Titles and abstracts relevant to SMBG and HbA1c were retrieved in a search of MEDLINE, published in English, for the years 1976 to July 2005. Search terms included, in various combinations: self-monitoring of blood glucose, SMBG, glycated hemoglobin, HbA1c, mean glycemia, confounder, standardization, efficacy, alternate site testing, frequency, postprandial, continuous glucose monitoring, fructosamine, screening, recommendations, NGSP [National Glycohemoglobin Standardization Program], IFCC [International Federation of Clinical Chemistry]. In limiting the number of articles evaluated, preference was given to larger cohort studies, randomized trials (especially those that enrolled ≥100 patients), prior comprehensive reviews, meta-analyses, quality of peer-reviewed publications, and published guidelines.

Self-monitoring of Blood Glucose

With a small fingerprick and a microliter or less of blood, people with diabetes can know their blood glucose level at any time. This allows patients to relate events in their daily life and treatment regimen to glycemic results. The introduction of SMBG thus caused a shift in the focus of diabetes management from the physician's office into the hands of the patient. Given proper understanding and communication with the health care professional, patients could, to an extent previously unheard of, take control of their own diabetes.

Current glucose monitors use glucose test strips impregnated with glucose oxidase, glucose dehydrogenase, or hexokinase to convert blood glucose into gluconic acid and hydrogen peroxide when a drop of blood is added to the strip. This reaction is then quantified by various means including colorimetric methods, reflectance photometry, absorbance photometry, and electrochemistry.11

Standardization and Confounders. In general, results from glucose meters are not as accurate as those from laboratory methods, although they are far more accurate than the earlier approach of visual matching to colors. While standards for acceptable accuracy vary, the International Organization for Standardization (http://www.iso.org) recommends that more than 95% of readings be within  15 mg/dL (0.83 mmol/L) for glucose readings that are less than 75 mg/dL (4.2 mmol/L), and within 20% for higher blood glucose values when compared with the standard YSI 2700 reference method (Yellow Springs Instruments, Yellow Springs, Ohio). Under optimal circumstances, many meters meet these accuracy standards12; however, there are confounding variables.

Quiz Ref IDOperator-related errors are a more significant source of error than are instrument-related errors.13 A significant between-patient variance has been reported in glucose meter readings,14 although the role of education in reducing user inaccuracies was demonstrated in a before-after study of 280 patients by Bergenstal et al.15 Patient failure to calibrate the glucose meter regularly is a common cause of error.12 Other common technique errors include improper use of control solutions, poor hand washing, and dirty meters.12 Improper storage of test strips, which exposes them to humidity or excessive temperature, can falsely elevate results.15 Certain drugs, such as ascorbic acid, acetaminophen, dopamine, and mannitol, can affect the accuracy of some meters.16 Glucose meters are also less reliable in the lower ranges of glycemia17 and may overestimate true glucose values in the high glycemic range.14

A low hematocrit increases SMBG results18 because of the lower erythrocyte mass. Erythrocytes are relatively glucopenic, so the whole blood applied to strips normally has about 15% less glucose than plasma glucose, the difference lessened with anemia. Most meters today are calibrated to provide plasma glucose equivalent readings19 and assume a normal hematocrit.

To reduce pain and promote more frequent testing, blood may be drawn from sites other than the fingertips, such as the forearm and thigh. This alternate site testing is a good option for routine SMBG testing before meals but may lead to false results after eating, exercising, or with insulin treatment.20,21 For example, compared with finger blood, forearm blood glucose appears to rise more slowly and less high after a small meal, whereas after exercise, thigh and forearm glucose levels fall lower than does fingertip glucose. Therefore, fingertip testing is preferred in circumstances of rapidly changing blood glucose levels.

Clinical Utility and Controversies. The age-adjusted percentage of adults with diabetes performing daily SMBG increased from 36% in 1994 to 58% in 2003.22 Frequency of SMBG varies directly with the intensity of treatment,23 and cost inhibits its use,24 either insured or out-of-pocket.25 Indeed, the cost of SMBG is considerable. The Medicare B program is said to have spent more than $460 million on SMBG reimbursement in 2002, more than half its Part B budget for the diabetes International Classification of Diseases, Ninth Revision code.26 It is therefore important to ask whether SMBG positively affects patient care.

Many studies have sought to answer this question (Table), but there are multiple sources of bias that are difficult to overcome. The population studied, the mode of treatment, duration of the trial, and study design all affect the generalizability of results. Uncontrollable bias is introduced if, for example, people who test regularly also have generally better self-care habits, or conversely, if individuals who test more often have less stable diabetes, and more need to know their blood glucose level. Even with a randomized controlled trial (RCT) design, the education level of the patient, and in particular how he or she is taught to take action based on results, could significantly influence the efficacy of SMBG.38,43 No information is available on patients who chose not to take part in studies, which further limits generalizability. Finally, there is little reason to think that testing without acting upon the results would be helpful.

Table Graphic Jump LocationTable. Clinical Trials of Self-monitoring of Blood Glucose

Early nonrandomized reports of SMBG were positive.4446 Four Veterans Administration studies, however, each reported no benefit to SMBG,4750 although 6 of the 10 other retrospective or cross-sectional studies23,4446,5156 did show benefit. A large cohort study of a managed care population of 24 000 patients found SMBG improved HbA1c by up to 1%.23 A Canadian cross-sectional study found patients who were insured for SMBG had significantly lower HbA 1c levels than those without coverage,52 and a study of 115 patients found that HbA1c was not affected by simply prescribing SMBG.53

Tapping National Health and Nutrition Examination Survey (NHANES) data cross-sectionally, Harris found more SMBG among insulin-treated people, but no relationship between frequency of HbA1c and SMBG54; Blonde et al disputed this finding.55 A recent evaluation from Italy found no effect of SMBG in people with type 2 diabetes not taking insulin,56 consistent with their previous emphasis on the need for an educational link to SMBG.57

RCTs have had more positive results, including all 6 of those studying more than 100 participants (Table). Kwon et al randomly assigned 110 patients to usual care or Internet-based evaluation of SMBG, finding that with rapid feedback, SMBG proved beneficial.28 Guerci et al in the Auto-Surveillance Intervention Active (ASIA) trial studied patients in 265 French physicians' offices, finding small but significant benefit from SMBG.36 Schwedes et al, in a German RCT of non−insulin-treated patients, found improved HbA1c with SMBG.35 A recent smaller study by Davidson et al stands out as a negative RCT. It found no effect of pre- and postprandial SMBG in 89 community clinic, non−insulin-treated participants of predominantly low socioeconomic status in Los Angeles, with educators blinded to group assignment.37

Two systematic reviews and 2 meta-analyses were reviewed (Table), all of people with non–insulin-treated diabetes. Faas, in 1997, noted no significant evidence of benefit in type 2 diabetes, but recommended more studies.38 The meta-analysis by Coster et al of 285 patients also found that blood or urine monitoring had nonsignificant effect.39 The 2 most recent reports, however, were positive. Sarol et al, summarized 8 RCTs of 1307 patients, and found a significant reduction in HbA 1c of approximately 0.4% among patients who performed SMBG.40 Welschen et al recently reviewed the literature for non–insulin-using people with diabetes, concluding that SMBG does have a favorable effect on HbA1c,41 although in a counterpoint, Davidson disputed the conclusion.26

In sum, the larger, more recent trials reviewed in this article support the conclusion that SMBG, if effectively translated into action, improves glycemia. The data are most conclusive for insulin-using people, in whom SMBG as part of a complete regimen to improve glycemia does reduce long-term complications of diabetes.1 The evidence that links SMBG to improved glycemia in non–insulin-requiring type 2 diabetes is less definitive.

Recommendations for Use. Consistent communication between the patient and health care professional is essential to effective implementation of self-monitoring and maintenance of patient motivation. When patients monitor regularly, they should be taught how to act immediately on the results as well as communicate the results to the health care professional. The health care professional must in turn take note of and evaluate results, communicate treatment modifications based on the results, and include follow-up.

Quiz Ref IDThere are no definitive clinical studies on optimal frequency of SMBG, so this is best decided by the individual patient and clinician. The American Diabetes Association (ADA) recommends SMBG 3 or more times daily for type 1 diabetes and no specific frequency is recommended for type 2.58 It is reasonable to recommend more frequent SMBG in people with more unstable glycemia, those prone to hypoglycemia, and when treatment changes are made. We believe that glycemic goals should be individualized, but the ADA has recommended that adults with type 1 or 2 diabetes aim for preprandial plasma glucose between 90 and 130 mg/dL (5.0-7.2 mmol/L) and peak postprandial plasma glucose less than 180 mg/dL (<10 mmol/L).58

The optimal timing of SMBG testing also remains controversial. Monnier et al have made the most detailed analyses of this issue.59,60 They found that the “extended post-lunch” (5 PM) values predicted HbA1c less than 7% with better sensitivity and specificity than did fasting glucose. But in less well-controlled type 2 patients, a 3-point daily testing system was optimal, one fasting (8 AM), one postprandial (10 AM), and one postabsorptive (5 PM). In people with type 1 diabetes, a 4- to 8-point daily system was recommended. In another study, peak post-lunch blood glucose values did not affect HbA1c after controlling for mean glycemia.61

In diabetic pregnancy, when the object is to approach euglycemia for the benefit of the developing fetus, postprandial testing has proven efficacy for both women with pregestational type 1 diabetes62 and women with gestational diabetes.63

Epidemiologic studies suggest that postprandial hyperglycemia is more predictive of adverse cardiovascular outcomes,64,65 but these effects are relatively small and the data are drawn mainly from populations with mild diabetes or even HbA1c within the normal range. It is not at all clear, therefore, that postprandial glucose measurements are predictive of cardiovascular or other diabetic complications beyond their effect on HbA1c. In other words, if preprandial SMBG and HbA1c values are in a good range, there is little evidence to recommend testing after a meal.

A consensus panel concluded that evidence is not adequate to support routine postprandial blood glucose testing.66 Uncertainty about exact timing postprandially and exact meal content were cited. Our practice is to rely on fasting, preprandial, and bedtime SMBG unless there is a special circumstance such as an unexplained discrepancy between HbA1c and SMBG results, pregnancy, or mild glucose intolerance. Also, given the potential seriousness of nocturnal hypoglycemia,67 it is clinically indicated to test in the middle of the night if patients have any symptomatic evidence of nighttime lows and to make appropriate treatment adjustments.

Patients using insulin pumps are a subgroup with special need for frequent blood glucose monitoring, both to guide their bolus insulin dosing and because if insulin delivery is inadvertently interrupted, they become insulinopenic very rapidly and ketoacidosis can develop quickly.68

SMBG can be used most effectively by using data management features available on the glucose meter to calculate means, variance, and trends by time-of-day or over weeks and months. Most meters can now easily download results into a personal computer, so managed data (graphs, averages) can be quickly printed. The only requirements are that the time and date be correctly entered into the meter, and that the office have a connecting cable and simple software. Examples of such downloads are in Figure 1 and Figure 2. In our opinion, this data management capability is useful and underutilized.

Figure 1. Sample Data Downloaded From Blood Glucose Meters by Time of Day
Graphic Jump Location

Sample data downloaded from blood glucose meters over the 90 days prior to the visit. In panel A, the patient clearly has good glycemic control during the day but levels are high between about 5 and 7 AM. This illustrates the “dawn phenomenon,” in which hyperglycemia occurs in the dawn hours. In panel B, the patient tests regularly 3 times daily and has much better, more stable glucose levels in the morning than at noon or at 5 PM, when the level is higher and more variable. Regimen adjustment could include more daytime insulin or oral agent coverage or modification of dietary intake.

Figure 2. Sample Data Downloaded From Blood Glucose Meters Continuously
Graphic Jump Location

Glycemic control is clearly worse throughout the month of March. The patient started a better nutritional plan in April and the results are evident. Discussion with the patient could include lessening antidiabetic treatment to avoid hypoglycemia.

The Future: Continuous Glucose Monitoring. Quiz Ref IDContinuous glucose monitoring (CGM) is in its infancy as a practical clinical tool, but it is likely to change diabetes management. Moving from intermittent SMBG to CGM is a conceptual as well as a technical advance. With CGM, the continuous, sometimes extreme fluctuations of blood glucose are readily apparent. Alarms can be set to alert patients of high or low blood glucose concentrations. The immediate effect of every dietary and therapeutic intervention can be seen.

At present, there are several CGM products on the market and more are under development.69 These monitors measure glucose concentration in subcutaneous interstitial fluid, which can reflect changes in blood glucose concentrations reasonably quickly.70,71 Recent reports describe the use of CGM in clinical and research settings,7274 but the monitors are not easily used on a routine, clinical, long-term basis. Spectroscopy-based75 and fluorescence-based sensors,76 which could be entirely noninvasive, have been slow to develop.

The ultimate goal of CGM is to drive a closed-loop insulin delivery system, the “artificial pancreas.”77 This goal, in early stages of development, depends on the sensors being robust, accurate, and easy to use.69

Hemoglobin A

In the late 1960s, a minor component of human hemoglobin A was noted to be increased in patients with diabetes.78 By the mid-1970s, HbA1c was shown to decrease as glycemic control improved, and thus, the potential of HbA1c as a clinical and research tool was recognized.79 Over the last 25 years, HbA1c testing has come into common use, serving as a convenient method for evaluating average glycemia over the previous several months.

HbA1c is defined as the stable adduct of glucose at the N-terminal amino group of the β-chain of hemoglobin Ao (N-[1-deoxyfructosyl]hemoglobin).80 It forms as a posttranslational modification, in which glucose condenses with the free amine group on the N-terminal valine residues of the hemoglobin β-chain. The resulting Schiff base is unstable and undergoes an irreversible Amadori rearrangement to form a stable ketoamine.81 Glycation also occurs at certain lysine residues on the hemoglobin α- and β-chains; total glycohemoglobin or total glycated hemoglobin refer to measurement of these products as well as HbA1c. Glycated hemoglobin is quantified most commonly with methods that distinguish it from nonglycated hemoglobin on the basis of either charge (cation-exchange chromatography, electrophoresis, isoelectric focusing) or structural characteristics (affinity chromatography, immunoassays).82

Quiz Ref IDA direct relationship exists between HbA1c and mean glycemia because erythrocytes are continuously glycated during their 120-day lifespan and the rate of glycohemoglobin formation is proportional to the ambient glucose concentration. In the Diabetes Control and Complications Trial, an HbA1c of 6% (measured by ion-exchange high-performance liquid chromatography) corresponded to a mean plasma glucose level of 135 mg/dL (7.5 mmol/L), and each 1% increase in HbA1c corresponded to an increase in mean plasma glucose level of approximately 35 mg/dL (2 mmol/L).83 One caveat in interpreting the linearity of this relationship is that HbA1c does not reflect blood glucose levels equally over the previous 120 days. Rather, recent changes in glycemic control are overrepresented in HbA1c. About 50% of HbA1c is determined by glycemia during the 1 month preceding the measurement, 25% from the 30 to 60 days before the measurement, and 25% from the 60 to 120 days prior to the measurement.84

Standardization and Confounders. Comparing study results and setting HbA1c goals assumes reliability and comparability of methods. In the early 1990s, there were over 20 available methods, with widely varying reference ranges. The National Glycohemoglobin Standardization Program (NGSP) (http://www.missouri.edu/~diabetes/ngsp.html) was created to remedy this situation and has been highly successful. Currently, 99% of laboratories in the United States use certified assays that are traceable to the Diabetes Control and Complications Trial glycohemoglobin reference (ion-exchange high-performance liquid chromatography) with a total imprecision (coefficient of variation) of 4% or less. Reliable standardization of the assay is also increasing internationally.

While age, sex, ethnicity, and nonfasting state do not affect HbA1c test results, confounding conditions do exist. Hemoglobin variants commonly and unpredictably interfere with HbA1c measurements. Hemoglobin S or C carriers may have spuriously high or low HbA1c results measured by ion-exchange high-performance liquid chromatography due to coelution of the variant with either HbA1c or HbA, and results may be affected when using other methods as well.85 With more than 700 hemoglobin variants reported, most clinically silent, unsuspected errors in HbA1c results may occur. Chemically modified hemoglobin, such as carbamylated hemoglobin associated with uremia and acetylated hemoglobin formed after ingestion of large doses of salicylates, can falsely increase results.86,87 A hemoglobin variant should be suspected if the HbA1c reading is surprisingly high or low, or is significantly changed coincident with a change in laboratory method. In these cases, a boronate affinity chromatography method of measuring HbA1c may be more reliable. Bry et al have reviewed this topic88 as has the NGSP Web site.

Many conditions also exist that alter HbA1c levels independent of the assay method. Any process that shortens erythrocyte lifespan decreases HbA1c, since glycation increases with age of the red cell. Kidney disease, liver disease, hemolytic anemia, hemoglobinopathies, and recovery from blood loss will all decrease HbA1c on this basis. Vitamins C and E have been reported to lower HbA1c measurements, possibly by inhibiting glycation.89,90 Lower HbA1c levels are found in diabetic and nondiabetic pregnant women, probably due both to lower fasting blood glucose and a shortened erythrocyte lifespan, prompting a proposal for lowering the upper normal limit for HbA1c in pregnancy.91

Iron-deficiency anemia, on the other hand, has been associated with increased HbA1c.92 Any process that slows erythropoesis, such as aplastic anemia, will increase HbA1c by causing an older erythrocyte cohort.

We studied whether glycemic lability, independent of mean glycemia, affects HbA1c. Analyzing the SD of blood glucose in patients performing frequent SMBG, we found that after controlling for mean glycemia, HbA1c is not affected by glycemic lability.93 Another report reached a similar conclusion on glycemia after lunch.62

Clinical Utility and Controversies. The measurement of HbA1c has been the primary index of glycemia in the Diabetes Control and Complications Trial, the United Kingdom Prospective Diabetes Study, and many other studies. It is therefore the basis upon which glycemic control is known to be a mediator of diabetic complications. The Diabetes Control and Complications Trial reduced mean HbA1c by 1.8% in the intensively treated group (7.3% vs 9.1%), and this difference resulted in a 76% (95% confidence interval [CI], 62%-85%) decrease in the development of new retinopathy, a 39% (95% CI, 21%-52%) reduction in microalbuminuria, and a 60% (95% CI, 38%-74%) decrease in the development of clinical neuropathy.1 Similarly, in type 2 diabetes, the United Kingdom Prospective Diabetes Study found a 25% (95% CI, 7%-40%) decrease in microvascular complications associated with the 10% reduction in HbA1c achieved in the intensively treated group.3

Surprisingly, the relatively short period of intensive control imposed in the Diabetes Control and Complications Trial has now been shown to have long-lasting beneficial effects years after the HbA1c levels of the groups merge.94,95 HbA1c is also the accepted measure of long-term glycemia in the Framingham65 prospective cohort study and the long-term follow-up study to the Diabetes Control and Complications Trial,96 both of which have found a lower risk for macrovascular complications with improved glycemia.

While abundant evidence demonstrates that improved HbA1c reduces the risk of complications, it is not clear whether regular assessment of HbA1c itself improves diabetic control. Larsen et al more than 15 years ago did find in an RCT of 240 patients with type 1 diabetes that treatment decisions made using quarterly HbA1c results were more successful in lowering future HbA1c results than those based only on blood or urine glucose testing.97

An outside analysis of the Diabetes Control and Complications Trial raised the theory that there are “fast glycators” who, independent of glycemia alone, may be at greater risk of diabetic complications.98,99 This theory is disputed,100,101 however, and most evidence supports the conclusion that HbA1c correlates with complication risk because it reflects glycemia, not because it causes complications directly.

Recently, NGSP-certified rapid HbA1c assays have become available, allowing office and home testing. Point-of-care HbA1c testing at the clinic visit gives patients immediate feedback and allows the physician to make timely therapy changes. RCT evidence suggests that point-of-care HbA1c testing may be superior to central laboratory testing in decreasing HbA1c levels in type 1 and type 2 diabetes.102,103 Benefits of home testing, including increased patient autonomy and self-knowledge, must be weighed against the possibility of misuse, misinterpretation, and avoidance of the regular medical care system. No evidence exists to evaluate home HbA1c testing.

In addition to HbA1c, 2 other long-term indicies of glycemia, fructosamine and 1,5 anhydroglucitol (1,5-AG), are available but less widely used. Fructosamine, the product of posttranslational glycation of serum proteins, predominantly albumin, provides a reflection of glycemia over a shorter time frame than does HbA1c. The reliability of the fructosamine assay is variable, bringing into question its clinical utility. One study found the mean glycemia over a prior 2-week period was better predicted by HbA1c than fructosamine.104 Even as an adjunct to home blood glucose monitoring, weekly fructosamine testing did not improve HbA1c levels.105

Recently, the US Food and Drug Administration approved a measure of the 1,5-AG assay. This measures serum levels of a molecule that is excreted in the urine with competitive inhibition by glucose. Thus, glucosuria inhibits 1,5-AG reabsorption at the renal tubule level, 1,5-AG excretion increases, and the serum levels fall with hyperglycemia. One study found an increase in 1,5-AG within 2 weeks of initiating treatment in patients with poorly controlled type 2 diabetes before a change in HbA1c was seen.106 In another study of 76 patients with well-controlled type 2 diabetes, 1,5-AG levels correlated with the degree of daily glycemic excursion, despite similar HbA1c values among treatment groups.107 The assay is marketed and could be useful as a marker of postprandial hyperglycemia, presumably because glycosuria ensues postprandially. Further studies are needed, however, to make a convincing case that 1,5-AG actually reflects postprandial hyperglycemia.

Recommendations. The relationship between control and complications is continuous, with no single glycemic threshold below which the risk of complications is sharply reduced or eliminated.108 Furthermore, the risk of hypoglycemia increases with lower HbA1c, at least in type 1 diabetes8 (less clearly for type 2 diabetes109,110). Therefore, determining a glycemic target involves considering the individual risk-benefit ratio; there is no scientific basis for choosing a single, universal target HbA1c.

The ADA currently recommends that patients with type 1 and 2 diabetes achieve HbA1c levels less than 7%,58 a level that confers a low risk of complications (eg, 9-year progression of rate of retinopathy <4%111). In some circumstances, such as elderly patients or those prone to hypoglycemia unawareness, target HbA1c should be adjusted upward, and some people with diabetes can achieve HbA1c of 6.5% or less. Studies to determine the ideal frequency of HbA1c testing are lacking, but expert opinion suggests twice-yearly testing in patients meeting goals and quarterly testing in patients not meeting goals or in whom therapy is changed.58

It remains controversial whether HbA1c should be accepted as a means of screening or diagnosing diabetes. It would provide a simple laboratory test that does not require the patient to fast and is not greatly affected by diet or activity level of the previous few days. Proponents also point to improvements in assay standardization112 that have improved sensitivity and specificity when compared with criterion standard oral glucose tolerance testing. Indeed, the specificity for detecting undiagnosed diabetes in one study was 97.4% for HbA1c results 2 SDs above the mean (>6.1%).113 At present, however, HbA1c testing is not accepted for screening or diagnostic purposes.58

The Future of HbA1c. The International Federation of Clinical Chemistry has developed a new, more specific reference method for measuring glycated hemoglobin.114 Using mass spectroscopy and capillary electrophoresis, this method assays the glycation of valine residues on hemoglobin. With this more specific measurement, the International Federation of Clinical Chemistry reference range is about 1.3% to 1.5% lower than NGSP values.115 The normal range would thus be approximately 2% to 4% rather than the present 4% to 6%, and all values in the diabetic range would be about 2% lower than we are used to. A strong correlation exists between the existing and the new assays, however, and a conversion equation has been developed.115

It is likely that this new International Federation of Clinical Chemistry method will become the anchor for glycated hemoglobin assays worldwide, but debate is ongoing as to how the new results will be reported, and even what the new test will be called. Changing the HbA1c reference range could cause confusion for professionals and the public alike, given the decades-long effort to educate people about the importance of measuring HbA1c and the goal of maintaining HbA1c at less than 7%. One study found that simply modifying HbA1c reference ranges caused a deterioration in glycemic control in patients.116 The new anchor could be converted to NGSP-standardized results and be reported in the familiar units. An alternative proposal is to conduct a large international trial, better establishing the exact relationship of the new results to mean blood glucose, and to change the name of the test from HbA1c to mean blood glucose equivalent. With a new reference range, new targets, and a new name, the results could be reported in familiar plasma glucose values rather than as percent HbA1c.117

Management of glycemia in diabetes is crucially important to the prevention of both acute and long-term complications. The 2 fundamental approaches to assessment, SMBG and HbA1c, provide fundamentally different but complementary information. Regular SMBG is to be encouraged, particularly in patients using insulin, although the frequency can vary widely dependent particularly on the glycemic stability of the patient and the need to follow treatment changes. HbA1c, the criterion standard measure of chronic glycemic control and complication risk, should be measured every 3 to 6 months to assess the success of the treatment regimen. Changes in both approaches are ongoing but with proper control of glycemia, diabetes can be successfully managed.

Corresponding Author: Christopher D. Saudek, MD, Osler 576, Johns Hopkins Hospital, 600 N Wolfe St, Baltimore, MD 21287 (csaudek@jhu.edu).

Author Contributions: Dr Saudek had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.

Study concept and design: Saudek, Derr, Kalyani.

Acquisition of data: Saudek, Kalyani.

Analysis and interpretation of data: Saudek, Derr, Kalyani.

Drafting of the manuscript: Saudek, Derr, Kalyani.

Critical revision of the manuscript for important intellectual content: Saudek, Derr, Kalyani.

Obtained funding: Saudek.

Administrative, technical, or material support: Saudek, Derr, Kalyani.

Study supervision: Saudek.

Financial Disclosures: Dr Saudek has delivered lectures sponsored by Lifescan Inc; has accepted insulin pumps for implanted insulin pump research from Medtronic MiniMed; and has received research support from DexCom Inc for studies of an implanted continuous glucose sensor. No products manufactured by the aforementioned companies were mentioned in this article. Drs Derr and Kalyani reported no financial disclosures.

Funding/Support: None disclosed.

Role of the Sponsor: The sponsor had no role in the design, conduct, or preparation of this manuscript.

 The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus: the Diabetes Control and Complications Trial Research Group.  N Engl J Med. 1993;329:977-986
PubMed   |  Link to Article
Ohkubo Y, Kishikawa H, Araki E.  et al.  Intensive insulin therapy prevents the progression of diabetic microvascular complications in japanese patients with non-insulin-dependent diabetes mellitus: a randomized prospective 6-year study.  Diabetes Res Clin Pract. 1995;28:103-117
PubMed   |  Link to Article
 Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33): UK Prospective Diabetes Study (UKPDS) group [published erratum appears in Lancet. 1999;354(9178):602].  Lancet. 1998;352:837-853
PubMed   |  Link to Article
 Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34): UK Prospective Diabetes Study (UKPDS) group [published erratum appears in Lancet. 1998;352(9139):1557].  Lancet. 1998;352:854-865
PubMed   |  Link to Article
Stratton IM, Adler AI, Neil HA.  et al.  Association of glycaemia with macrovascular and microvascular complications of type 2 diabetes (UKPDS 35): prospective observational study.  BMJ. 2000;321:405-412
PubMed   |  Link to Article
Smith NL, Barzilay JI, Shaffer D.  et al.  Fasting and 2-hour postchallenge serum glucose measures and risk of incident cardiovascular events in the elderly: the Cardiovascular Health Study.  Arch Intern Med. 2002;162:209-216
PubMed   |  Link to Article
Selvin E, Marinopoulos S, Berkenblit G.  et al.  Meta-analysis: glycosylated hemoglobin and cardiovascular disease in diabetes mellitus.  Ann Intern Med. 2004;141:421-431
PubMed   |  Link to Article
 The Diabetes Control and Complications Trial research group. Hypoglycemia in the diabetes control and complications trial.  Diabetes. 1997;46:271-286
PubMed   |  Link to Article
 Influence of intensive diabetes treatment on quality-of-life outcomes in the diabetes control and complications trial [see comments].  Diabetes Care. 1996;19:195-203
PubMed   |  Link to Article
Bliss M. The Discovery of Insulin. Chicago, Ill: University of Chicago Press; 1982
Marks V. Blood glucose: its measurement and clinical importance.  Clin Chim Acta. 1996;251:3-17
PubMed   |  Link to Article
Johnson RN, Baker JR. Error detection and measurement in glucose monitors.  Clin Chim Acta. 2001;307:61-67
PubMed   |  Link to Article
Lewandrowski K, Cheek R, Nathan DM.  et al.  Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testing.  Am J Med. 1992;93:419-426
PubMed   |  Link to Article
Brunner GA, Ellmerer M, Sendlhofer G.  et al.  Validation of home blood glucose meters with respect to clinical and analytical approaches.  Diabetes Care. 1998;21:585-590
PubMed   |  Link to Article
Bergenstal R, Pearson J, Cembrowski GS, Bina D, Davidson J, List S. Identifying variables associated with inaccurate self-monitoring of blood glucose: proposed guidelines to improve accuracy.  Diabetes Educ. 2000;26:981-989
PubMed   |  Link to Article
Tang Z, Du X, Louie RF, Kost GJ. Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer.  Am J Clin Pathol. 2000;113:75-86
PubMed   |  Link to Article
Trajanoski Z, Brunner GA, Gfrerer RJ, Wach P, Pieber TR. Accuracy of home blood glucose meters during hypoglycemia.  Diabetes Care. 1996;19:1412-1415
PubMed   |  Link to Article
Wiener K. The effect of haematocrit on reagent strip tests for glucose.  Diabet Med. 1991;8:172-175
PubMed   |  Link to Article
Goldstein DE, Little RR, Lorenz RA.  et al.  Tests of glycemia in diabetes.  Diabetes Care. 2004;27:S91-S93
PubMed   |  Link to Article
Ellison JM, Stegmann JM, Colner SL.  et al.  Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites.  Diabetes Care. 2002;25:961-964
PubMed   |  Link to Article
Bina DM, Anderson RL, Johnson ML, Bergenstal RM, Kendall DM. Clinical impact of prandial state, exercise, and site preparation on the equivalence of alternative-site blood glucose testing.  Diabetes Care. 2003;26:981-985
PubMed   |  Link to Article
 Age-adjusted rates of annual dilated-eye exam, daily self-monitoring of blood glucose, foot examination in the last year, and doctor visit for diabetes in the last year per 100 adults with diabetes, United States, 1994-2004. Centers for Disease Control and Prevention Web site. Available at: http://www.cdc.gov/diabetes/statistics/preventive/tx.htm. Accessed March 14, 2006
Karter AJ, Ackerson LM, Darbinian JA.  et al.  Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes Registry.  Am J Med. 2001;111:1-9
PubMed   |  Link to Article
Soumerai SB, Mah C, Zhang F.  et al.  Effects of health maintenance organization coverage of self-monitoring devices on diabetes self-care and glycemic control.  Arch Intern Med. 2004;164:645-652
PubMed   |  Link to Article
Karter AJ, Stevens MR, Herman WH.  et al.  Out-of-pocket costs and diabetes preventive services: the translating research into action for diabetes (TRIAD) study.  Diabetes Care. 2003;26:2294-2299
PubMed   |  Link to Article
Davidson MB. Counterpoint: self-monitoring of blood glucose in type 2 diabetic patients not receiving insulin—a waste of money.  Diabetes Care. 2005;28:1531-1533
PubMed   |  Link to Article
Wing RR, Epstein LH, Nowalk MP, Scott N, Koeske R, Hagg S. Does self-monitoring of blood glucose levels improve dietary compliance for obese patients with type II diabetes?  Am J Med. 1986;81:830-836
PubMed   |  Link to Article
Kwon HS, Cho JH, Kim HS.  et al.  Establishment of blood glucose monitoring system using the Internet.  Diabetes Care. 2004;27:478-483
PubMed   |  Link to Article
Fontbonne A, Billault B, Acosta M.  et al.  Is glucose self-monitoring beneficial in non-insulin-treated diabetic patients? results of a randomized comparative trial.  Diabete Metab. 1989;15:255-260
PubMed
Allen BT, DeLong ER, Feussner JR. Impact of glucose self-monitoring on non-insulin-treated patients with type II diabetes mellitus: randomized controlled trial comparing blood and urine testing.  Diabetes Care. 1990;13:1044-1050
PubMed   |  Link to Article
Estey AL, Tan MH, Mann K. Follow-up intervention: its effect on compliance behavior to a diabetes regimen.  Diabetes Educ. 1990;16:291-295
PubMed   |  Link to Article
Rutten G, van Eijk J, de Nobel E, Beek M, van der Velden H. Feasibility and effects of a diabetes type II protocol with blood glucose self-monitoring in general practice.  Fam Pract. 1990;7:273-278
PubMed   |  Link to Article
Muchmore DB, Springer J, Miller M. Self-monitoring of blood glucose in overweight type 2 diabetic patients.  Acta Diabetol. 1994;31:215-219
PubMed   |  Link to Article
Jaber LA, Halapy H, Fernet M, Tummalapalli S, Diwakaran H. Evaluation of a pharmaceutical care model on diabetes management.  Ann Pharmacother. 1996;30:238-243
PubMed
Schwedes U, Siebolds M, Mertes G.SMBG Study Group.  Meal-related structured self-monitoring of blood glucose: effect on diabetes control in non-insulin-treated type 2 diabetic patients.  Diabetes Care. 2002;25:1928-1932
PubMed   |  Link to Article
Guerci B, Drouin P, Grange V.  et al.  Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) study.  Diabetes Metab. 2003;29:587-594
PubMed   |  Link to Article
Davidson MB, Castellanos M, Kain D, Duran P. The effect of self monitoring of blood glucose concentrations on glycated hemoglobin levels in diabetic patients not taking insulin: a blinded, randomized trial.  Am J Med. 2005;118:422-425
PubMed   |  Link to Article
Faas A, Schellevis FG, Van Eijk JT. The efficacy of self-monitoring of blood glucose in NIDDM subjects. a criteria-based literature review.  Diabetes Care. 1997;20:1482-1486
PubMed   |  Link to Article
Coster S, Gulliford MC, Seed PT, Powrie JK, Swaminathan R. Self-monitoring in type 2 diabetes mellitus: a meta-analysis.  Diabet Med. 2000;17:755-761
PubMed   |  Link to Article
Sarol JN Jr, Nicodemus NA Jr, Tan KM, Grava MB. Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004).  Curr Med Res Opin. 2005;21:173-184
PubMed   |  Link to Article
Welschen LM, Bloemendal E, Nijpels G.  et al.  Self-monitoring of blood glucose in patients with type 2 diabetes who are not using insulin: a systematic review.  Diabetes Care. 2005;28:1510-1517
PubMed   |  Link to Article
Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.  Clin Chem. 2002;48:436-472
PubMed
Wysocki T. Impact of blood glucose monitoring on diabetic control: obstacles and interventions.  J Behav Med. 1989;12:183-205
PubMed   |  Link to Article
Sonksen PH, Judd SL, Lowy C. Home monitoring of blood-glucose: method for improving diabetic control.  Lancet. 1978;1:729-732
PubMed   |  Link to Article
Walford S, Gale EA, Allison SP, Tattersall RB. Self-monitoring of blood-glucose: improvement of diabetic control.  Lancet. 1978;1:732-735
PubMed   |  Link to Article
Cohen M, Zimmet P. Self-monitoring of blood glucose levels in non-insulin-dependent diabetes mellitus.  Med J Aust. 1983;2:377-380
PubMed
Newman WP, Laqua D, Engelbrecht D. Impact of glucose self-monitoring on glycohemoglobin values in a veteran population.  Arch Intern Med. 1990;150:107-110
PubMed   |  Link to Article
Klein CE, Oboler SK, Prochazka A.  et al.  Home blood glucose monitoring: effectiveness in a general population of patients who have non-insulin-dependent diabetes mellitus.  J Gen Intern Med. 1993;8:597-601
PubMed   |  Link to Article
Wieland LD, Vigil JM, Hoffman RM, Janis LW. Relationship between home glucose testing and hemoglobin alc in type II diabetes patients.  Am J Health Syst Pharm. 1997;54:1062-1065
PubMed
Wen L, Parchman ML, Linn WD, Lee S. Association between self-monitoring of blood glucose and glycemic control in patients with type 2 diabetes mellitus.  Am J Health Syst Pharm. 2004;61:2401-2405
PubMed
Oki JC, Flora DL, Isley WL. Frequency and impact of SMBG on glycemic control in patients with NIDDM in an urban teaching hospital clinic.  Diabetes Educ. 1997;23:419-424
PubMed   |  Link to Article
Bowker SL, Mitchell CG, Majumdar SR, Toth EL, Johnson JA. Lack of insurance coverage for testing supplies is associated with poorer glycemic control in patients with type 2 diabetes.  CMAJ. 2004;171:39-43
PubMed   |  Link to Article
Rindone JP, Austin M, Luchesi J. Effect of home blood glucose monitoring on the management of patients with non-insulin dependent diabetes mellitus in the primary care setting.  Am J Manag Care. 1997;3:1335-1338
PubMed
Harris MI.National Health and Nutrition Examination Survey (NHANES III).  Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes.  Diabetes Care. 2001;24:979-982
PubMed   |  Link to Article
Blonde L, Ginsberg BH, Horn S.  et al.  Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes.  Diabetes Care. 2002;25:245-246
PubMed   |  Link to Article
Franciosi M, Pellegrini F, De Berardis G.  et al.  Self-monitoring of blood glucose in non-insulin-treated diabetic patients: a longitudinal evaluation of its impact on metabolic control.  Diabet Med. 2005;22:900-906
PubMed   |  Link to Article
Franciosi M, Pellegrini F, De Berardis G.  et al.  The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients: an urgent need for better educational strategies.  Diabetes Care. 2001;24:1870-1877
PubMed   |  Link to Article
 Standards of medical care in diabetes.  Diabetes Care. 2005;28:S4-S36
PubMed   |  Link to Article
Monnier L, Colette C, Lapinski H, Boniface H. Self-monitoring of blood glucose in diabetic patients: from the least common denominator to the greatest common multiple.  Diabetes Metab. 2004;30:113-119
PubMed   |  Link to Article
Monnier L, Lapinski H, Colette C. Contributions of fasting and postprandial plasma glucose increments to the overall diurnal hyperglycemia of type 2 diabetic patients: variations with increasing levels of HbA(1c).  Diabetes Care. 2003;26:881-885
PubMed   |  Link to Article
Salardi S, Zucchini S, Santoni R.  et al.  The glucose area under the profiles obtained with continuous glucose monitoring system relationships with HbA(1c) in pediatric type 1 diabetic patients.  Diabetes Care. 2002;25:1840-1844
PubMed   |  Link to Article
Manderson JG, Patterson CC, Hadden DR, Traub AI, Ennis C, McCance DR. Preprandial versus postprandial blood glucose monitoring in type 1 diabetic pregnancy: a randomized controlled clinical trial.  Am J Obstet Gynecol. 2003;189:507-512
PubMed   |  Link to Article
de Veciana M, Major CA, Morgan MA.  et al.  Postprandial versus preprandial blood glucose monitoring in women with gestational diabetes mellitus requiring insulin therapy.  N Engl J Med. 1995;333:1237-1241
PubMed   |  Link to Article
Hanefeld M, Fischer S, Julius U.  et al.  Risk factors for myocardial infarction and death in newly detected NIDDM: the diabetes intervention study, 11-year follow-up.  Diabetologia. 1996;39:1577-1583
PubMed   |  Link to Article
Meigs JB, Nathan DM, D'Agostino RB Sr, Wilson PW.Framingham Offspring Study.  Fasting and postchallenge glycemia and cardiovascular disease risk.  Diabetes Care. 2002;25:1845-1850
PubMed   |  Link to Article
American Diabetes Association.  Postprandial blood glucose.  Diabetes Care. 2001;24:775-778
PubMed   |  Link to Article
Tattersall RB, Gill GV. Unexplained deaths of type 1 diabetic patients.  Diabet Med. 1991;8:49-58
PubMed   |  Link to Article
Pickup JC, Viberti GC, Bilous RW.  et al.  Safety of continuous subcutaneous insulin infusion: metabolic deterioration and glycaemic autoregulation after deliberate cessation of infusion.  Diabetologia. 1982;22:175-179
PubMed   |  Link to Article
Chia CW, Saudek CD. Glucose sensors: toward closed loop insulin delivery.  Endocrinol Metab Clin North Am. 2004;33:175-195
PubMed   |  Link to Article
Rebrin K, Steil GM, van Antwerp WP, Mastrototaro JJ. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring.  Am J Physiol. 1999;277:E561-E571
PubMed
Rebrin K, Steil GM. Can interstitial glucose assessment replace blood glucose measurements?  Diabetes Technol Ther. 2000;2:461-472
PubMed   |  Link to Article
Tanenberg R, Bode B, Lane W.  et al.  Use of the continuous glucose monitoring system to guide therapy in patients with insulin-treated diabetes: a randomized controlled trial.  Mayo Clin Proc. 2004;79:1521-1526
PubMed   |  Link to Article
Tansey MJ, Beck RW, Buckingham BA.  et al.  Accuracy of the modified continuous glucose monitoring system (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study.  Diabetes Technol Ther. 2005;7:109-114
PubMed   |  Link to Article
Goldberg PA, Siegel MD, Russell RR.  et al.  Experience with the continuous glucose monitoring system in a medical intensive care unit.  Diabetes Technol Ther. 2004;6:339-347
PubMed   |  Link to Article
Cohen O, Fine I, Monashkin E, Karasik A. Glucose correlation with light scattering patterns–a novel method for non-invasive glucose measurements.  Diabetes Technol Ther. 2003;5:11-17
PubMed   |  Link to Article
Pickup JC, Hussain F, Evans ND, Rolinski OJ, Birch DJ. Fluorescence-based glucose sensors.  Biosens Bioelectron. 2005;20:2555-2565
PubMed   |  Link to Article
Saudek CD, Chia CW. International Textbook of Diabetes Mellitus, Vol 2; 2. Implantable pumps. In: Ralph A, DeFronzo EF, Keen H, Zimmet P, eds. 3rd ed. Chichester, England: John Wiley & Sons, Ltd; 2004:1037
Rahbar S, Blumenfeld O, Ranney HM. Studies of an unusual hemoglobin in patients with diabetes mellitus.  Biochem Biophys Res Commun. 1969;36:838-843
PubMed   |  Link to Article
Koenig RJ, Peterson CM, Jones RL, Saudek C, Lehrman M, Cerami A. Correlation of glucose regulation and hemoglobin A1c in diabetes mellitus.  N Engl J Med. 1976;295:417-420
PubMed   |  Link to Article
Peterson KP, Pavlovich JG, Goldstein D, Little R, England J, Peterson CM. What is hemoglobin A1c? an analysis of glycated hemoglobins by electrospray ionization mass spectrometry.  Clin Chem. 1998;44:1951-1958
PubMed
Bunn HF, Haney DN, Kamin S, Gabbay KH, Gallop PM. The biosynthesis of human hemoglobin A1c. slow glycosylation of hemoglobin in vivo.  J Clin Invest. 1976;57:1652-1659
PubMed   |  Link to Article
Goldstein DE, Little RR, Lorenz RA.  et al.  Tests of glycemia in diabetes.  Diabetes Care. 2004;27:1761-1773
PubMed   |  Link to Article
Rohlfing CL, Wiedmeyer HM, Little RR, England JD, Tennill A, Goldstein DE. Defining the relationship between plasma glucose and HbA(1c): analysis of glucose profiles and HbA(1c) in the diabetes control and complications trial.  Diabetes Care. 2002;25:275-278
PubMed   |  Link to Article
Tahara Y, Shima K. The response of GHb to stepwise plasma glucose change over time in diabetic patients.  Diabetes Care. 1993;16:1313-1314
PubMed
Roberts WL, Safar-Pour S, De BK, Rohlfing CL, Weykamp CW, Little RR. Effects of hemoglobin C and S traits on glycohemoglobin measurements by eleven methods.  Clin Chem. 2005;51:776-778
PubMed   |  Link to Article
Chachou A, Randoux C, Millart H, Chanard J, Gillery P. Influence of in vivo hemoglobin carbamylation on HbA1c measurements by various methods.  Clin Chem Lab Med. 2000;38:321-326
PubMed   |  Link to Article
Nathan DM, Francis TB, Palmer JL. Effect of aspirin on determinations of glycosylated hemoglobin.  Clin Chem. 1983;29:466-469
PubMed
Bry L, Chen PC, Sacks DB. Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin.  Clin Chem. 2001;47:153-163
PubMed
Davie SJ, Gould BJ, Yudkin JS. Effect of vitamin C on glycosylation of proteins.  Diabetes. 1992;41:167-173
PubMed   |  Link to Article
Ceriello A, Giugliano D, Quatraro A, Donzella C, Dipalo G, Lefebvre PJ. Vitamin E reduction of protein glycosylation in diabetes. new prospect for prevention of diabetic complications?  Diabetes Care. 1991;14:68-72
PubMed   |  Link to Article
Nielsen LR, Ekbom P, Damm P.  et al.  HbA1c levels are significantly lower in early and late pregnancy.  Diabetes Care. 2004;27:1200-1201
PubMed   |  Link to Article
Tarim O, Kucukerdogan A, Gunay U, Eralp O, Ercan I. Effects of iron deficiency anemia on hemoglobin A1c in type 1 diabetes mellitus.  Pediatr Int. 1999;41:357-362
PubMed
Derr R, Garrett E, Stacy GA, Saudek CD. Is HbA(1c) affected by glycemic instability?  Diabetes Care. 2003;26:2728-2733
PubMed   |  Link to Article
 Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus.  JAMA. 2002;287:2563-2569
PubMed   |  Link to Article
 Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic nephropathy: the epidemiology of diabetes interventions and complications (EDIC) study.  JAMA. 2003;290:2159-2167
PubMed   |  Link to Article
Nathan DM, Cleary PA, Backlund JY.  et al.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes.  N Engl J Med. 2005;353:2643-2653
PubMed   |  Link to Article
Larsen ML, Horder M, Mogensen EF. Effect of long-term monitoring of glycosylated hemoglobin levels in insulin-dependent diabetes mellitus.  N Engl J Med. 1990;323:1021-1025
PubMed   |  Link to Article
Hempe JM, Gomez R, McCarter RJ Jr, Chalew SA. High and low hemoglobin glycation phenotypes in type 1 diabetes: a challenge for interpretation of glycemic control.  J Diabetes Complications. 2002;16:313-320
PubMed   |  Link to Article
McCarter RJ, Hempe JM, Gomez R, Chalew SA. Biological variation in HbA1c predicts risk of retinopathy and nephropathy in type 1 diabetes.  Diabetes Care. 2004;27:1259-1264
PubMed   |  Link to Article
Genuth S, Lachin JM, Nathan DM. Biological variation in HbA1c predicts risk of retinopathy and nephropathy in type 1 diabetes: response to McCarter et al.  Diabetes Care. 2005;28:233-235
PubMed   |  Link to Article
Rohlfing C, Wiedmeyer HM, Little R.  et al.  Biological variation of glycohemoglobin.  Clin Chem. 2002;48:1116-1118
PubMed
Cagliero E, Levina EV, Nathan DM. Immediate feedback of HbA1c levels improves glycemic control in type 1 and insulin-treated type 2 diabetic patients.  Diabetes Care. 1999;22:1785-1789
PubMed   |  Link to Article
Miller CD, Barnes CS, Phillips LS.  et al.  Rapid A1c availability improves clinical decision-making in an urban primary care clinic.  Diabetes Care. 2003;26:1158-1163
PubMed   |  Link to Article
Cefalu WT, Wang ZQ, Bell-Farrow A, Kiger FD, Izlar C. Glycohemoglobin measured by automated affinity HPLC correlates with both short-term and long-term antecedent glycemia.  Clin Chem. 1994;40:1317-1321
PubMed
Lindsey CC, Carter AW, Mangum S.  et al.  A prospective, randomized, multicentered controlled trial to compare the annual glycemic and quality outcomes of patients with diabetes mellitus monitored with weekly fructosamine testing versus usual care.  Diabetes Technol Ther. 2004;6:370-377
PubMed   |  Link to Article
McGill JB, Cole TG, Nowatzke W.  et al.  Circulating 1,5-anhydroglucitol levels in adult patients with diabetes reflect longitudinal changes of glycemia: a U.S. trial of the GlycoMark assay.  Diabetes Care. 2004;27:1859-1865
PubMed   |  Link to Article
Kishimoto M, Yamasaki Y, Kubota M.  et al.  1,5-anhydro-D-glucitol evaluates daily glycemic excursions in well-controlled NIDDM.  Diabetes Care. 1995;18:1156-1159
PubMed   |  Link to Article
 The absence of a glycemic threshold for the development of long-term complications: the perspective of the diabetes control and complications trial.  Diabetes. 1996;45:1289-1298
PubMed   |  Link to Article
Colwell JA. Intensive insulin therapy in type II diabetes: rationale and collaborative clinical trial results.  Diabetes. 1996;45:(suppl 396289846)  S87-S90
PubMed
 UKPDS 28: a randomized trial of efficacy of early addition of metformin in sulfonylurea-treated type 2 diabetes: U.K. Prospective Diabetes Study Group.  Diabetes Care. 1998;21:87-92
PubMed   |  Link to Article
 The relationship of glycemic exposure (HbA1c) to the risk of development and progression of retinopathy in the diabetes control and complications trial.  Diabetes. 1995;44:968-983
PubMed   |  Link to Article
Barr RG, Nathan DM, Meigs JB, Singer DE. Tests of glycemia for the diagnosis of type 2 diabetes mellitus.  Ann Intern Med. 2002;137:263-272
PubMed   |  Link to Article
Rohlfing CL, Little RR, Wiedmeyer HM.  et al.  Use of GHb (HbA1c) in screening for undiagnosed diabetes in the U.S. population.  Diabetes Care. 2000;23:187-191
PubMed   |  Link to Article
Jeppsson JO, Kobold U, Barr J.  et al.  Approved IFCC reference method for the measurement of HbA1c in human blood.  Clin Chem Lab Med. 2002;40:78-89
PubMed   |  Link to Article
Hoelzel W, Weykamp C, Jeppsson JO.  et al.  IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.  Clin Chem. 2004;50:166-174
PubMed   |  Link to Article
Hanas R. Psychological impact of changing the scale of reported HbA(1c) results affects metabolic control.  Diabetes Care. 2002;25:2110-2111
PubMed   |  Link to Article
Sacks DB.ADA/EASD/IDF Working Group of the HbA1c Assay.  Global harmonization of hemoglobin A1c.  Clin Chem. 2005;51:681-683
PubMed   |  Link to Article

Figures

Figure 1. Sample Data Downloaded From Blood Glucose Meters by Time of Day
Graphic Jump Location

Sample data downloaded from blood glucose meters over the 90 days prior to the visit. In panel A, the patient clearly has good glycemic control during the day but levels are high between about 5 and 7 AM. This illustrates the “dawn phenomenon,” in which hyperglycemia occurs in the dawn hours. In panel B, the patient tests regularly 3 times daily and has much better, more stable glucose levels in the morning than at noon or at 5 PM, when the level is higher and more variable. Regimen adjustment could include more daytime insulin or oral agent coverage or modification of dietary intake.

Figure 2. Sample Data Downloaded From Blood Glucose Meters Continuously
Graphic Jump Location

Glycemic control is clearly worse throughout the month of March. The patient started a better nutritional plan in April and the results are evident. Discussion with the patient could include lessening antidiabetic treatment to avoid hypoglycemia.

Tables

Table Graphic Jump LocationTable. Clinical Trials of Self-monitoring of Blood Glucose

References

 The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus: the Diabetes Control and Complications Trial Research Group.  N Engl J Med. 1993;329:977-986
PubMed   |  Link to Article
Ohkubo Y, Kishikawa H, Araki E.  et al.  Intensive insulin therapy prevents the progression of diabetic microvascular complications in japanese patients with non-insulin-dependent diabetes mellitus: a randomized prospective 6-year study.  Diabetes Res Clin Pract. 1995;28:103-117
PubMed   |  Link to Article
 Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33): UK Prospective Diabetes Study (UKPDS) group [published erratum appears in Lancet. 1999;354(9178):602].  Lancet. 1998;352:837-853
PubMed   |  Link to Article
 Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34): UK Prospective Diabetes Study (UKPDS) group [published erratum appears in Lancet. 1998;352(9139):1557].  Lancet. 1998;352:854-865
PubMed   |  Link to Article
Stratton IM, Adler AI, Neil HA.  et al.  Association of glycaemia with macrovascular and microvascular complications of type 2 diabetes (UKPDS 35): prospective observational study.  BMJ. 2000;321:405-412
PubMed   |  Link to Article
Smith NL, Barzilay JI, Shaffer D.  et al.  Fasting and 2-hour postchallenge serum glucose measures and risk of incident cardiovascular events in the elderly: the Cardiovascular Health Study.  Arch Intern Med. 2002;162:209-216
PubMed   |  Link to Article
Selvin E, Marinopoulos S, Berkenblit G.  et al.  Meta-analysis: glycosylated hemoglobin and cardiovascular disease in diabetes mellitus.  Ann Intern Med. 2004;141:421-431
PubMed   |  Link to Article
 The Diabetes Control and Complications Trial research group. Hypoglycemia in the diabetes control and complications trial.  Diabetes. 1997;46:271-286
PubMed   |  Link to Article
 Influence of intensive diabetes treatment on quality-of-life outcomes in the diabetes control and complications trial [see comments].  Diabetes Care. 1996;19:195-203
PubMed   |  Link to Article
Bliss M. The Discovery of Insulin. Chicago, Ill: University of Chicago Press; 1982
Marks V. Blood glucose: its measurement and clinical importance.  Clin Chim Acta. 1996;251:3-17
PubMed   |  Link to Article
Johnson RN, Baker JR. Error detection and measurement in glucose monitors.  Clin Chim Acta. 2001;307:61-67
PubMed   |  Link to Article
Lewandrowski K, Cheek R, Nathan DM.  et al.  Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testing.  Am J Med. 1992;93:419-426
PubMed   |  Link to Article
Brunner GA, Ellmerer M, Sendlhofer G.  et al.  Validation of home blood glucose meters with respect to clinical and analytical approaches.  Diabetes Care. 1998;21:585-590
PubMed   |  Link to Article
Bergenstal R, Pearson J, Cembrowski GS, Bina D, Davidson J, List S. Identifying variables associated with inaccurate self-monitoring of blood glucose: proposed guidelines to improve accuracy.  Diabetes Educ. 2000;26:981-989
PubMed   |  Link to Article
Tang Z, Du X, Louie RF, Kost GJ. Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer.  Am J Clin Pathol. 2000;113:75-86
PubMed   |  Link to Article
Trajanoski Z, Brunner GA, Gfrerer RJ, Wach P, Pieber TR. Accuracy of home blood glucose meters during hypoglycemia.  Diabetes Care. 1996;19:1412-1415
PubMed   |  Link to Article
Wiener K. The effect of haematocrit on reagent strip tests for glucose.  Diabet Med. 1991;8:172-175
PubMed   |  Link to Article
Goldstein DE, Little RR, Lorenz RA.  et al.  Tests of glycemia in diabetes.  Diabetes Care. 2004;27:S91-S93
PubMed   |  Link to Article
Ellison JM, Stegmann JM, Colner SL.  et al.  Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites.  Diabetes Care. 2002;25:961-964
PubMed   |  Link to Article
Bina DM, Anderson RL, Johnson ML, Bergenstal RM, Kendall DM. Clinical impact of prandial state, exercise, and site preparation on the equivalence of alternative-site blood glucose testing.  Diabetes Care. 2003;26:981-985
PubMed   |  Link to Article
 Age-adjusted rates of annual dilated-eye exam, daily self-monitoring of blood glucose, foot examination in the last year, and doctor visit for diabetes in the last year per 100 adults with diabetes, United States, 1994-2004. Centers for Disease Control and Prevention Web site. Available at: http://www.cdc.gov/diabetes/statistics/preventive/tx.htm. Accessed March 14, 2006
Karter AJ, Ackerson LM, Darbinian JA.  et al.  Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes Registry.  Am J Med. 2001;111:1-9
PubMed   |  Link to Article
Soumerai SB, Mah C, Zhang F.  et al.  Effects of health maintenance organization coverage of self-monitoring devices on diabetes self-care and glycemic control.  Arch Intern Med. 2004;164:645-652
PubMed   |  Link to Article
Karter AJ, Stevens MR, Herman WH.  et al.  Out-of-pocket costs and diabetes preventive services: the translating research into action for diabetes (TRIAD) study.  Diabetes Care. 2003;26:2294-2299
PubMed   |  Link to Article
Davidson MB. Counterpoint: self-monitoring of blood glucose in type 2 diabetic patients not receiving insulin—a waste of money.  Diabetes Care. 2005;28:1531-1533
PubMed   |  Link to Article
Wing RR, Epstein LH, Nowalk MP, Scott N, Koeske R, Hagg S. Does self-monitoring of blood glucose levels improve dietary compliance for obese patients with type II diabetes?  Am J Med. 1986;81:830-836
PubMed   |  Link to Article
Kwon HS, Cho JH, Kim HS.  et al.  Establishment of blood glucose monitoring system using the Internet.  Diabetes Care. 2004;27:478-483
PubMed   |  Link to Article
Fontbonne A, Billault B, Acosta M.  et al.  Is glucose self-monitoring beneficial in non-insulin-treated diabetic patients? results of a randomized comparative trial.  Diabete Metab. 1989;15:255-260
PubMed
Allen BT, DeLong ER, Feussner JR. Impact of glucose self-monitoring on non-insulin-treated patients with type II diabetes mellitus: randomized controlled trial comparing blood and urine testing.  Diabetes Care. 1990;13:1044-1050
PubMed   |  Link to Article
Estey AL, Tan MH, Mann K. Follow-up intervention: its effect on compliance behavior to a diabetes regimen.  Diabetes Educ. 1990;16:291-295
PubMed   |  Link to Article
Rutten G, van Eijk J, de Nobel E, Beek M, van der Velden H. Feasibility and effects of a diabetes type II protocol with blood glucose self-monitoring in general practice.  Fam Pract. 1990;7:273-278
PubMed   |  Link to Article
Muchmore DB, Springer J, Miller M. Self-monitoring of blood glucose in overweight type 2 diabetic patients.  Acta Diabetol. 1994;31:215-219
PubMed   |  Link to Article
Jaber LA, Halapy H, Fernet M, Tummalapalli S, Diwakaran H. Evaluation of a pharmaceutical care model on diabetes management.  Ann Pharmacother. 1996;30:238-243
PubMed
Schwedes U, Siebolds M, Mertes G.SMBG Study Group.  Meal-related structured self-monitoring of blood glucose: effect on diabetes control in non-insulin-treated type 2 diabetic patients.  Diabetes Care. 2002;25:1928-1932
PubMed   |  Link to Article
Guerci B, Drouin P, Grange V.  et al.  Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) study.  Diabetes Metab. 2003;29:587-594
PubMed   |  Link to Article
Davidson MB, Castellanos M, Kain D, Duran P. The effect of self monitoring of blood glucose concentrations on glycated hemoglobin levels in diabetic patients not taking insulin: a blinded, randomized trial.  Am J Med. 2005;118:422-425
PubMed   |  Link to Article
Faas A, Schellevis FG, Van Eijk JT. The efficacy of self-monitoring of blood glucose in NIDDM subjects. a criteria-based literature review.  Diabetes Care. 1997;20:1482-1486
PubMed   |  Link to Article
Coster S, Gulliford MC, Seed PT, Powrie JK, Swaminathan R. Self-monitoring in type 2 diabetes mellitus: a meta-analysis.  Diabet Med. 2000;17:755-761
PubMed   |  Link to Article
Sarol JN Jr, Nicodemus NA Jr, Tan KM, Grava MB. Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004).  Curr Med Res Opin. 2005;21:173-184
PubMed   |  Link to Article
Welschen LM, Bloemendal E, Nijpels G.  et al.  Self-monitoring of blood glucose in patients with type 2 diabetes who are not using insulin: a systematic review.  Diabetes Care. 2005;28:1510-1517
PubMed   |  Link to Article
Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.  Clin Chem. 2002;48:436-472
PubMed
Wysocki T. Impact of blood glucose monitoring on diabetic control: obstacles and interventions.  J Behav Med. 1989;12:183-205
PubMed   |  Link to Article
Sonksen PH, Judd SL, Lowy C. Home monitoring of blood-glucose: method for improving diabetic control.  Lancet. 1978;1:729-732
PubMed   |  Link to Article
Walford S, Gale EA, Allison SP, Tattersall RB. Self-monitoring of blood-glucose: improvement of diabetic control.  Lancet. 1978;1:732-735
PubMed   |  Link to Article
Cohen M, Zimmet P. Self-monitoring of blood glucose levels in non-insulin-dependent diabetes mellitus.  Med J Aust. 1983;2:377-380
PubMed
Newman WP, Laqua D, Engelbrecht D. Impact of glucose self-monitoring on glycohemoglobin values in a veteran population.  Arch Intern Med. 1990;150:107-110
PubMed   |  Link to Article
Klein CE, Oboler SK, Prochazka A.  et al.  Home blood glucose monitoring: effectiveness in a general population of patients who have non-insulin-dependent diabetes mellitus.  J Gen Intern Med. 1993;8:597-601
PubMed   |  Link to Article
Wieland LD, Vigil JM, Hoffman RM, Janis LW. Relationship between home glucose testing and hemoglobin alc in type II diabetes patients.  Am J Health Syst Pharm. 1997;54:1062-1065
PubMed
Wen L, Parchman ML, Linn WD, Lee S. Association between self-monitoring of blood glucose and glycemic control in patients with type 2 diabetes mellitus.  Am J Health Syst Pharm. 2004;61:2401-2405
PubMed
Oki JC, Flora DL, Isley WL. Frequency and impact of SMBG on glycemic control in patients with NIDDM in an urban teaching hospital clinic.  Diabetes Educ. 1997;23:419-424
PubMed   |  Link to Article
Bowker SL, Mitchell CG, Majumdar SR, Toth EL, Johnson JA. Lack of insurance coverage for testing supplies is associated with poorer glycemic control in patients with type 2 diabetes.  CMAJ. 2004;171:39-43
PubMed   |  Link to Article
Rindone JP, Austin M, Luchesi J. Effect of home blood glucose monitoring on the management of patients with non-insulin dependent diabetes mellitus in the primary care setting.  Am J Manag Care. 1997;3:1335-1338
PubMed
Harris MI.National Health and Nutrition Examination Survey (NHANES III).  Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes.  Diabetes Care. 2001;24:979-982
PubMed   |  Link to Article
Blonde L, Ginsberg BH, Horn S.  et al.  Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes.  Diabetes Care. 2002;25:245-246
PubMed   |  Link to Article
Franciosi M, Pellegrini F, De Berardis G.  et al.  Self-monitoring of blood glucose in non-insulin-treated diabetic patients: a longitudinal evaluation of its impact on metabolic control.  Diabet Med. 2005;22:900-906
PubMed   |  Link to Article
Franciosi M, Pellegrini F, De Berardis G.  et al.  The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients: an urgent need for better educational strategies.  Diabetes Care. 2001;24:1870-1877
PubMed   |  Link to Article
 Standards of medical care in diabetes.  Diabetes Care. 2005;28:S4-S36
PubMed   |  Link to Article
Monnier L, Colette C, Lapinski H, Boniface H. Self-monitoring of blood glucose in diabetic patients: from the least common denominator to the greatest common multiple.  Diabetes Metab. 2004;30:113-119
PubMed   |  Link to Article
Monnier L, Lapinski H, Colette C. Contributions of fasting and postprandial plasma glucose increments to the overall diurnal hyperglycemia of type 2 diabetic patients: variations with increasing levels of HbA(1c).  Diabetes Care. 2003;26:881-885
PubMed   |  Link to Article
Salardi S, Zucchini S, Santoni R.  et al.  The glucose area under the profiles obtained with continuous glucose monitoring system relationships with HbA(1c) in pediatric type 1 diabetic patients.  Diabetes Care. 2002;25:1840-1844
PubMed   |  Link to Article
Manderson JG, Patterson CC, Hadden DR, Traub AI, Ennis C, McCance DR. Preprandial versus postprandial blood glucose monitoring in type 1 diabetic pregnancy: a randomized controlled clinical trial.  Am J Obstet Gynecol. 2003;189:507-512
PubMed   |  Link to Article
de Veciana M, Major CA, Morgan MA.  et al.  Postprandial versus preprandial blood glucose monitoring in women with gestational diabetes mellitus requiring insulin therapy.  N Engl J Med. 1995;333:1237-1241
PubMed   |  Link to Article
Hanefeld M, Fischer S, Julius U.  et al.  Risk factors for myocardial infarction and death in newly detected NIDDM: the diabetes intervention study, 11-year follow-up.  Diabetologia. 1996;39:1577-1583
PubMed   |  Link to Article
Meigs JB, Nathan DM, D'Agostino RB Sr, Wilson PW.Framingham Offspring Study.  Fasting and postchallenge glycemia and cardiovascular disease risk.  Diabetes Care. 2002;25:1845-1850
PubMed   |  Link to Article
American Diabetes Association.  Postprandial blood glucose.  Diabetes Care. 2001;24:775-778
PubMed   |  Link to Article
Tattersall RB, Gill GV. Unexplained deaths of type 1 diabetic patients.  Diabet Med. 1991;8:49-58
PubMed   |  Link to Article
Pickup JC, Viberti GC, Bilous RW.  et al.  Safety of continuous subcutaneous insulin infusion: metabolic deterioration and glycaemic autoregulation after deliberate cessation of infusion.  Diabetologia. 1982;22:175-179
PubMed   |  Link to Article
Chia CW, Saudek CD. Glucose sensors: toward closed loop insulin delivery.  Endocrinol Metab Clin North Am. 2004;33:175-195
PubMed   |  Link to Article
Rebrin K, Steil GM, van Antwerp WP, Mastrototaro JJ. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring.  Am J Physiol. 1999;277:E561-E571
PubMed
Rebrin K, Steil GM. Can interstitial glucose assessment replace blood glucose measurements?  Diabetes Technol Ther. 2000;2:461-472
PubMed   |  Link to Article
Tanenberg R, Bode B, Lane W.  et al.  Use of the continuous glucose monitoring system to guide therapy in patients with insulin-treated diabetes: a randomized controlled trial.  Mayo Clin Proc. 2004;79:1521-1526
PubMed   |  Link to Article
Tansey MJ, Beck RW, Buckingham BA.  et al.  Accuracy of the modified continuous glucose monitoring system (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study.  Diabetes Technol Ther. 2005;7:109-114
PubMed   |  Link to Article
Goldberg PA, Siegel MD, Russell RR.  et al.  Experience with the continuous glucose monitoring system in a medical intensive care unit.  Diabetes Technol Ther. 2004;6:339-347
PubMed   |  Link to Article
Cohen O, Fine I, Monashkin E, Karasik A. Glucose correlation with light scattering patterns–a novel method for non-invasive glucose measurements.  Diabetes Technol Ther. 2003;5:11-17
PubMed   |  Link to Article
Pickup JC, Hussain F, Evans ND, Rolinski OJ, Birch DJ. Fluorescence-based glucose sensors.  Biosens Bioelectron. 2005;20:2555-2565
PubMed   |  Link to Article
Saudek CD, Chia CW. International Textbook of Diabetes Mellitus, Vol 2; 2. Implantable pumps. In: Ralph A, DeFronzo EF, Keen H, Zimmet P, eds. 3rd ed. Chichester, England: John Wiley & Sons, Ltd; 2004:1037
Rahbar S, Blumenfeld O, Ranney HM. Studies of an unusual hemoglobin in patients with diabetes mellitus.  Biochem Biophys Res Commun. 1969;36:838-843
PubMed   |  Link to Article
Koenig RJ, Peterson CM, Jones RL, Saudek C, Lehrman M, Cerami A. Correlation of glucose regulation and hemoglobin A1c in diabetes mellitus.  N Engl J Med. 1976;295:417-420
PubMed   |  Link to Article
Peterson KP, Pavlovich JG, Goldstein D, Little R, England J, Peterson CM. What is hemoglobin A1c? an analysis of glycated hemoglobins by electrospray ionization mass spectrometry.  Clin Chem. 1998;44:1951-1958
PubMed
Bunn HF, Haney DN, Kamin S, Gabbay KH, Gallop PM. The biosynthesis of human hemoglobin A1c. slow glycosylation of hemoglobin in vivo.  J Clin Invest. 1976;57:1652-1659
PubMed   |  Link to Article
Goldstein DE, Little RR, Lorenz RA.  et al.  Tests of glycemia in diabetes.  Diabetes Care. 2004;27:1761-1773
PubMed   |  Link to Article
Rohlfing CL, Wiedmeyer HM, Little RR, England JD, Tennill A, Goldstein DE. Defining the relationship between plasma glucose and HbA(1c): analysis of glucose profiles and HbA(1c) in the diabetes control and complications trial.  Diabetes Care. 2002;25:275-278
PubMed   |  Link to Article
Tahara Y, Shima K. The response of GHb to stepwise plasma glucose change over time in diabetic patients.  Diabetes Care. 1993;16:1313-1314
PubMed
Roberts WL, Safar-Pour S, De BK, Rohlfing CL, Weykamp CW, Little RR. Effects of hemoglobin C and S traits on glycohemoglobin measurements by eleven methods.  Clin Chem. 2005;51:776-778
PubMed   |  Link to Article
Chachou A, Randoux C, Millart H, Chanard J, Gillery P. Influence of in vivo hemoglobin carbamylation on HbA1c measurements by various methods.  Clin Chem Lab Med. 2000;38:321-326
PubMed   |  Link to Article
Nathan DM, Francis TB, Palmer JL. Effect of aspirin on determinations of glycosylated hemoglobin.  Clin Chem. 1983;29:466-469
PubMed
Bry L, Chen PC, Sacks DB. Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin.  Clin Chem. 2001;47:153-163
PubMed
Davie SJ, Gould BJ, Yudkin JS. Effect of vitamin C on glycosylation of proteins.  Diabetes. 1992;41:167-173
PubMed   |  Link to Article
Ceriello A, Giugliano D, Quatraro A, Donzella C, Dipalo G, Lefebvre PJ. Vitamin E reduction of protein glycosylation in diabetes. new prospect for prevention of diabetic complications?  Diabetes Care. 1991;14:68-72
PubMed   |  Link to Article
Nielsen LR, Ekbom P, Damm P.  et al.  HbA1c levels are significantly lower in early and late pregnancy.  Diabetes Care. 2004;27:1200-1201
PubMed   |  Link to Article
Tarim O, Kucukerdogan A, Gunay U, Eralp O, Ercan I. Effects of iron deficiency anemia on hemoglobin A1c in type 1 diabetes mellitus.  Pediatr Int. 1999;41:357-362
PubMed
Derr R, Garrett E, Stacy GA, Saudek CD. Is HbA(1c) affected by glycemic instability?  Diabetes Care. 2003;26:2728-2733
PubMed   |  Link to Article
 Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus.  JAMA. 2002;287:2563-2569
PubMed   |  Link to Article
 Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic nephropathy: the epidemiology of diabetes interventions and complications (EDIC) study.  JAMA. 2003;290:2159-2167
PubMed   |  Link to Article
Nathan DM, Cleary PA, Backlund JY.  et al.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes.  N Engl J Med. 2005;353:2643-2653
PubMed   |  Link to Article
Larsen ML, Horder M, Mogensen EF. Effect of long-term monitoring of glycosylated hemoglobin levels in insulin-dependent diabetes mellitus.  N Engl J Med. 1990;323:1021-1025
PubMed   |  Link to Article
Hempe JM, Gomez R, McCarter RJ Jr, Chalew SA. High and low hemoglobin glycation phenotypes in type 1 diabetes: a challenge for interpretation of glycemic control.  J Diabetes Complications. 2002;16:313-320
PubMed   |  Link to Article
McCarter RJ, Hempe JM, Gomez R, Chalew SA. Biological variation in HbA1c predicts risk of retinopathy and nephropathy in type 1 diabetes.  Diabetes Care. 2004;27:1259-1264
PubMed   |  Link to Article
Genuth S, Lachin JM, Nathan DM. Biological variation in HbA1c predicts risk of retinopathy and nephropathy in type 1 diabetes: response to McCarter et al.  Diabetes Care. 2005;28:233-235
PubMed   |  Link to Article
Rohlfing C, Wiedmeyer HM, Little R.  et al.  Biological variation of glycohemoglobin.  Clin Chem. 2002;48:1116-1118
PubMed
Cagliero E, Levina EV, Nathan DM. Immediate feedback of HbA1c levels improves glycemic control in type 1 and insulin-treated type 2 diabetic patients.  Diabetes Care. 1999;22:1785-1789
PubMed   |  Link to Article
Miller CD, Barnes CS, Phillips LS.  et al.  Rapid A1c availability improves clinical decision-making in an urban primary care clinic.  Diabetes Care. 2003;26:1158-1163
PubMed   |  Link to Article
Cefalu WT, Wang ZQ, Bell-Farrow A, Kiger FD, Izlar C. Glycohemoglobin measured by automated affinity HPLC correlates with both short-term and long-term antecedent glycemia.  Clin Chem. 1994;40:1317-1321
PubMed
Lindsey CC, Carter AW, Mangum S.  et al.  A prospective, randomized, multicentered controlled trial to compare the annual glycemic and quality outcomes of patients with diabetes mellitus monitored with weekly fructosamine testing versus usual care.  Diabetes Technol Ther. 2004;6:370-377
PubMed   |  Link to Article
McGill JB, Cole TG, Nowatzke W.  et al.  Circulating 1,5-anhydroglucitol levels in adult patients with diabetes reflect longitudinal changes of glycemia: a U.S. trial of the GlycoMark assay.  Diabetes Care. 2004;27:1859-1865
PubMed   |  Link to Article
Kishimoto M, Yamasaki Y, Kubota M.  et al.  1,5-anhydro-D-glucitol evaluates daily glycemic excursions in well-controlled NIDDM.  Diabetes Care. 1995;18:1156-1159
PubMed   |  Link to Article
 The absence of a glycemic threshold for the development of long-term complications: the perspective of the diabetes control and complications trial.  Diabetes. 1996;45:1289-1298
PubMed   |  Link to Article
Colwell JA. Intensive insulin therapy in type II diabetes: rationale and collaborative clinical trial results.  Diabetes. 1996;45:(suppl 396289846)  S87-S90
PubMed
 UKPDS 28: a randomized trial of efficacy of early addition of metformin in sulfonylurea-treated type 2 diabetes: U.K. Prospective Diabetes Study Group.  Diabetes Care. 1998;21:87-92
PubMed   |  Link to Article
 The relationship of glycemic exposure (HbA1c) to the risk of development and progression of retinopathy in the diabetes control and complications trial.  Diabetes. 1995;44:968-983
PubMed   |  Link to Article
Barr RG, Nathan DM, Meigs JB, Singer DE. Tests of glycemia for the diagnosis of type 2 diabetes mellitus.  Ann Intern Med. 2002;137:263-272
PubMed   |  Link to Article
Rohlfing CL, Little RR, Wiedmeyer HM.  et al.  Use of GHb (HbA1c) in screening for undiagnosed diabetes in the U.S. population.  Diabetes Care. 2000;23:187-191
PubMed   |  Link to Article
Jeppsson JO, Kobold U, Barr J.  et al.  Approved IFCC reference method for the measurement of HbA1c in human blood.  Clin Chem Lab Med. 2002;40:78-89
PubMed   |  Link to Article
Hoelzel W, Weykamp C, Jeppsson JO.  et al.  IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.  Clin Chem. 2004;50:166-174
PubMed   |  Link to Article
Hanas R. Psychological impact of changing the scale of reported HbA(1c) results affects metabolic control.  Diabetes Care. 2002;25:2110-2111
PubMed   |  Link to Article
Sacks DB.ADA/EASD/IDF Working Group of the HbA1c Assay.  Global harmonization of hemoglobin A1c.  Clin Chem. 2005;51:681-683
PubMed   |  Link to Article
CME


You need to register in order to view this quiz.

Multimedia

Some tools below are only available to our subscribers or users with an online account.

Web of Science® Times Cited: 133

Related Content

Customize your page view by dragging & repositioning the boxes below.

See Also...
Articles Related By Topic
Related Collections
PubMed Articles
JAMAevidence.com